Product Details
3.1 Key Specifications/Special Features
Ratings
Power supply voltage |
|
Power consumption |
24 VAC/DC: 1.8 VA/1 W max.
100 to 240 VAC: 2.5 VA max. |
Rated insulation
voltage |
600 VAC |
Operating value setting
range (SV) |
10% to 100% of maximum setting range |
Operating value |
100% operation at set value |
Reset value setting range (HYS) |
5% to 50% of operating value |
Reset method |
Note:Manual reset: Turn OFF power supply for
1 s or longer. |
Operating time setting
range (T) |
3to8 s |
Indicators |
Normal : Green light; Overvoltage Undervoltage : Yellow light |
Output form |
one Normally open and one normally closed |
Output relay ratings |
Rated load
5 A at 250 VAC (Resistive load)
5 A at 30 VDC (Resistive load)
1 A at 250 VAC (Inductive load)
0.2 A at 48 VDC (Inductive load)
Minimum load: 5 VDC, 10 mA (reference values)
Mechanical life: 10 million operations min.
Electrical life: 5 A at 250 VAC or 30 VDC: 50,000
operations
3 A at 250 VAC or 30 VDC:
100,000 operations |
Ambient operating
temperature |
-20 to 60°C (with no condensation or icing) |
Storage temperature |
-25 to 65°C (with no condensation or icing) |
Ambient operating
humidity |
25% to 85% RH (with no condensation) |
Storage humidity |
25% to 85% RH (with no condensation) |
Altitude |
2,000 m max. |
Applicable wires |
Stranded wires, solid wires, or ferrules |
Applicable wire size |
0.25 to 1.5 mm2(AWG24 to AWG16) |
Wire insertion force |
8 N max. for AWG20 wire |
Screwdriver insertion force |
15 N max. |
Wire stripping length |
8 mm |
Ferrule length |
8 mm |
Current capacity |
10 A (per pole) |
Weight |
Approx. 60 g |
Mounting |
Mounts to DIN Track |
Dimensions |
30 *60 *76 mm (W*H*D) |
Specifications
Conforming
standards |
EN 60947-5-1
Installation environment (pollution level 2, Overvoltage category III) |
Insulation resistance |
20 MΩmin.
Between external terminals and case
Between power supply terminals and input terminals
Between power supply terminals and output terminals
Between input terminals and output terminals |
Dielectric strength |
2,000 VAC for one minute
Between external terminals and case
Between power supply terminals and input terminals
Between power supply terminals and output terminals
Between input terminals and output terminals |
Impulse withstand
voltage |
6 kV (between live terminals and exposed, non-charged metal parts) |
Vibration resistance |
Frequency: 10 to 55 Hz, 0.35-mm single amplitude
10 sweeps of 5 min each in X,Y, and Z directions |
Shock resistance |
100 m/s2, 3 times each in 6 directions along 3 axes |
Degree of protection |
Terminals: IP20 |
Industry Category
|
Electrical-Equipment-Supplies/Electronic-Instrument-Enclosures
|
Product Category
|
|
Brand:
|
chfnad
|
Spec:
|
WXL-3-5
|
Stock:
|
|
Origin:
|
|